Nuclear Logging Rules of Thumb
|
|
|
|
|
|
|
|
|
|
|
|
Trial Time Constant (TC) in Seconds:
400 Counts per Second (cps) .
(Hottest Zone cps) - (Coldest Zone cps)
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
Log Speed in Feet per Minute (fpm) for 1 Foot Lag:
60 .
TC
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
Time Constant (TC) in Seconds for a Given Line Speed for 1 Foot Lag:
60 .
fpm
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
In the Illinois Basin, try 20 fpm with a 3 second Time Constant (TC).
|
|
|
|
|
|
|
|
|