Home

Nuclear Logging Rules of Thumb
Trial Time Constant (TC) in Seconds:

          400 Counts per Second (cps)           .
(Hottest Zone cps) - (Coldest Zone cps)
Log Speed in Feet per Minute (fpm) for 1 Foot Lag:
    60   .
TC
Time Constant (TC) in Seconds for a Given Line Speed for 1 Foot Lag:
     60    .
fpm
In the Illinois Basin, try 20 fpm with a 3 second Time Constant (TC).